NET_BOM CONFIG SETTING TABS |
---|
ADMIN |
GENERAL |
NETLIST_BOM_DIFF |
NETLIST_CONVERT |
ADMIN Configuration Settings Back to Top | |||
---|---|---|---|
Configuration Setting | Description | Value Current Default | Type |
CE_DOC_INDEX_URL | CadEnhance Website documentation table | current:default= https://www.cadEnhance.com/Documentation/index.html | Entry |
CE_JIRA_URL | Link to Jira Based Customer Service Portal | current:default= https://cadenhance.atlassian.net/servicedesk/customer/user/login?destination=portals | Entry |
CE_SAMPLE_PARTS_URL | This is where sample parts will be downloaded from | current:default= http://www.cadenhance.com/sample_part_downloads | Entry |
CE_SCAST_URL | Link to CadEnhance Tutorial and Example Videos | current:default= http://scast.cadenhance.com | Entry |
CE_SDL_PREPROC_DOC_URL | Link to OnLine Documentation for SDL Preprocessor Commands | current:default= https://cadenhance.atlassian.net/wiki/spaces/PD/pages/4098967/SDL+PreProcessor+commands | Entry |
CE_SITE_DB_URL | license code web address | current:default= https://www.cadenhance.com/api/php/cad_main.php | Entry |
CE_USER_GUIDE_URL | CadEnhance online UserGuide | current:default= http://docs.cadEnhance.com | Entry |
CE_VERSION_INFO_URL | Link to the ReadMe File for Tool Version changes | current:default= http://www.cadenhance.com/ce_tool_downloads/ce_win_readme.html | Entry |
HELP_INDEX_URL | This is a pointer to the index.html for the help information available for NetBom | current:default= www.cadenhance.com/Documentation/NetBom/index.html | Entry |
LIC_EXP_N_WEEKS_EARLY | Test Variable which enables us to reject the license early | current:default= '' | Entry |
NEW_TOOL_DOWNLOAD_URL | This is where I check for new tool releases | current:default= http://www.cadenhance.com/ce_tool_downloads/index.html | Entry |
Back to Top |
GENERAL Configuration Settings Back to Top | |||
---|---|---|---|
Configuration Setting | Description | Value Current Default | Type |
CE_LIC_FILE | Location of LICENSE FILE The system defaults to the setting of the CE_LIC_FILE Enviornment variable, but that can be overridden with this entry | current:D:/cadEnhance/license/license.dat default:'' | CHOOSE_FILE |
CE_WORK_DIR | This is the default location where part folders will be created | current:default= C:/cadEnhance/workdir | Entry |
LIC_WARNING_WEEKS | A warning will popup if the license is due to expire within this number of weeks | current:default= 4 | Entry |
OUTPUT_FILE_DIR | This is the directory that NetBom will use when it creates output files | current:default= cadEnhance/NetBom | Entry |
SHOW_DEBUG | determines whether DEBUG information is shown/hidden in Progress window | current:default= '' | CHECK_BUTTON |
SHOW_STAT | determines whether normal STATUS information is shown/hidden in Progress window | current:default= 1 | CHECK_BUTTON |
SHOW_WARN | determines whether WARNINGS are shown/hidden in Progress window | current:default= 1 | CHECK_BUTTON |
TEXT_EDITOR | Text Editor for editing files | current:default= '' | CHOOSE_FILE |
Back to Top |
NETLIST_BOM_DIFF Configuration Settings Back to Top | |||
---|---|---|---|
Configuration Setting | Description | Value Current Default | Type |
IGNORE_NET_PROP_DIFFS | Property names listed in this comma separated list
will be ignored when properties for the same NET_NAME in the 2 netLists are compared The following properties are never compared so they should not need to be added NET_NAME NET_CONNS NET_ID_FROM_PINS NET_ID_XCHECKED NL_INDEX NODE_LIST HIER_NET_NAME LOGICAL_PATH C_SIGNAL The user can look at the net_prop difference report and add any properties to this list that they do not want to include in the comparison | current:default= '' | Entry |
IGNORE_NODE_PROP_DIFFS | Property names listed in this comma separated list
will be ignored when properties for the same net node (refDes.Pin) in the 2 netLists are compared The following properties are never compared so they should not need to be added The user can look at the node_prop difference report and add any properties to this list that they do not want to include in the comparison | current:default= '' | Entry |
KEY_PROP_LIST | The BOM_DIFF engine will compare these properties for each refdes in the 2 bom revisions and report if they are different... it is a comma seperated list like: JEDEC_TYPE,VALUE,TYPE | current:default= JEDEC_TYPE, VALUE, TYPE | Entry |
MAX_TABLE_COL_WIDTH | If the data in a column in one of the report table exceeds this length, the code will add a line break for that column | current:default= 48 | Entry |
NETLIST1 | NETLIST1 use for diffing and converting netlists. You choose the pstxnet.dat file and netBom will find the matching pstxprt.dat | current:D:/Allegro/design/CE_SCHEMATICS/16_6/FOX/200-000307-FOX_SGDD/REV-01X/017_REV_1/worklib/top/packaged/pstxnet.dat default:'' | CHOOSE_FILE |
NETLIST2 | NETLIST2 for diffing BOMs and NETLISTS. You choose the pstxnet.dat file and NetBom will find the matching pstxprt.dat | current:D:/Allegro/design/CE_SCHEMATICS/16_6/FOX/200-000307-FOX_SGDD/REV-00X/007_REV_1/worklib/top/packaged/pstxnet.dat default:'' | CHOOSE_FILE |
OUTPUT_BOM_DIFF_FILE | Difference Report for the BOMs (from the pstxprt files), will be automatically named when you run the diff operation | current:cadEnhance/NetBom/bom1_diff_bom2.txt default:'' | CHOOSE_FILE |
OUTPUT_NET_DIFF_FILE | Difference Report for the NETLISTs (from the pstxnet files), will be automatically named when you run the diff operation | current:cadEnhance/NetBom/net1_diff_net2.txt default:'' | CHOOSE_FILE |
SINGLE_NODE_NET_FILTERS | This Comma Separated List is used to validate SINGLE NODE NETS.
If a NET_NAME contains any of these matches, and it only contains a single node, it will be counted as filtered, but not included in the SINGLE_NODE_NET report table | current:default= NC_, _NC, NC, ^$UN | Entry |
DNI_TRUE_VALS | This is a list of the values that make the DO_NOT_INSTALL_PROP true (comma seperated vals like:TRUE,1,YES) | current:default= TRUE, 1, YES | Entry |
DO_NOT_INSTALL_PROP | This is a comma seperated list of properties that will be used to determine if a part is not included in a BOM Could look like BOM_IGNORE,DNI. Any part with this Property found True will not be included in the BOM (unlike the BOM_NO_POP_PROP) | current:default= BOM_IGNORE | Entry |
NO_STRIP_PATH | Dont strip off the leading directory path for selected files | current:default= 1 | CHECK_BUTTON |
REFDES_RENAME_RULES | Comma Separated List of Was:Is rules to change reference designators in an existing netlist.
This can be used when the user knows they are changing many refdes in the new NetList and they don't want them to show up in the difference reports Example: _57$:_S5_S7,_46$:_S4_S6,_02$:_S0_S2,_13$:_S1_S3 this will replace any location ending in _57 with _S5_S7, _46 with S4_S6, _02 with S2_S2, _13 with S1_S3, | current:default= '' | Entry |
BOM_NO_POP_PROP | This Setting is used to pick a list of properties that excludes a reference designators from installation, but keeps the part in the BOM for purchasing When the BOM is generated by the netlist convert routine, any parts with this property found to be true will be printed on a separate row. | current:default= DNI | Entry |
BOM_NO_PROP_TRUE_VALS | This Setting is used to pick a property and value that excludes reference designators from installation, but keeps the part in the BOM for purchasing When the BOM is generated by the netlist convert routine, any parts with this property enabled will be printed on a separate row. | current:default= TRUE, YES, 1 | Entry |
Back to Top |
NETLIST_CONVERT Configuration Settings Back to Top | |||
---|---|---|---|
Configuration Setting | Description | Value Current Default | Type |
DNI_TRUE_VALS | This is a list of the values that make the DO_NOT_INSTALL_PROP true (comma seperated vals like:TRUE,1,YES) | current:default= TRUE, 1, YES | Entry |
DO_NOT_INSTALL_PROP | This is a comma seperated list of properties that will be used to determine if a part is not included in a BOM Could look like BOM_IGNORE,DNI. Any part with this Property found True will not be included in the BOM (unlike the BOM_NO_POP_PROP) | current:default= BOM_IGNORE | Entry |
NO_STRIP_PATH | Dont strip off the leading directory path for selected files | current:default= 1 | CHECK_BUTTON |
REFDES_RENAME_RULES | Comma Separated List of Was:Is rules to change reference designators in an existing netlist.
This can be used when the user knows they are changing many refdes in the new NetList and they don't want them to show up in the difference reports Example: _57$:_S5_S7,_46$:_S4_S6,_02$:_S0_S2,_13$:_S1_S3 this will replace any location ending in _57 with _S5_S7, _46 with S4_S6, _02 with S2_S2, _13 with S1_S3, | current:default= '' | Entry |
ADD_PIN_NAME_IN_RINF | If enabled, adds an extra debug level to RINF, showing the PIN_NAME next to the pin number | current:default= 1 | CHECK_BUTTON |
BOM_HEADER_PROPERTIES | This Setting controls what Properties are included in the output BOM from the netlist convert operation It is entered as a comma separated list, and the order of the Properties will be the order of the columns in the BOM The user can add any property that is defined for a part | current:default= PART_NUMBER, QTY, REF_DES, DESCRIPTION | Entry |
NL_ITEM_CELLS_PER_ROW | this is the number of cells that will be placed in a row for the output csv netlists/partlists | current:default= 25 | Entry |
RINF_PRINT_COMPONENTS | Chooses whether to include Component information to the Converted RINF Netlist | current:default= 1 | CHECK_BUTTON |
RINF_PRINT_NETS | Chooses whether to include Net information to the Converted RINF Netlist | current:default= 1 | CHECK_BUTTON |
RINF_PRINT_NET_PROPS | determines whether Net Properties will be printed in RINF netlist | current:default= '' | CHECK_BUTTON |
RINF_PRINT_PIN_PROPS | determines whether Pin Properties will be printed in RINF netlist | current:default= '' | CHECK_BUTTON |
BOM_NO_POP_PROP | This Setting is used to pick a list of properties that excludes a reference designators from installation, but keeps the part in the BOM for purchasing When the BOM is generated by the netlist convert routine, any parts with this property found to be true will be printed on a separate row. | current:default= DNI | Entry |
BOM_NO_PROP_TRUE_VALS | This Setting is used to pick a property and value that excludes reference designators from installation, but keeps the part in the BOM for purchasing When the BOM is generated by the netlist convert routine, any parts with this property enabled will be printed on a separate row. | current:default= TRUE, YES, 1 | Entry |
Back to Top |