NET_BOM CONFIGURATION SETTINGS REPORT

Version_Info=v19.3.1
Built:Tue Mar 05 15:04:03 2019

ConfigFile=netBomCtl.txt
NET_BOM CONFIG SETTING TABS
ADMIN
GENERAL
NETLIST_BOM_DIFF
NETLIST_CONVERT
ADMIN Configuration Settings Back to Top
Configuration SettingDescriptionValue
Current
Default
Type
CE_DOC_INDEX_URLCadEnhance Website documentation tablecurrent:default= https://www.cadEnhance.com/Documentation/index.htmlEntry
CE_JIRA_URLLink to Jira Based Customer Service Portalcurrent:default= https://cadenhance.atlassian.net/servicedesk/customer/user/login?destination=portalsEntry
CE_SAMPLE_PARTS_URLThis is where sample parts will be downloaded from current:default= http://www.cadenhance.com/sample_part_downloadsEntry
CE_SCAST_URLLink to CadEnhance Tutorial and Example Videoscurrent:default= http://scast.cadenhance.comEntry
CE_SDL_PREPROC_DOC_URLLink to OnLine Documentation for SDL Preprocessor Commandscurrent:default= https://cadenhance.atlassian.net/wiki/spaces/PD/pages/4098967/SDL+PreProcessor+commandsEntry
CE_SITE_DB_URLlicense code web addresscurrent:default= https://www.cadenhance.com/api/php/cad_main.phpEntry
CE_USER_GUIDE_URLCadEnhance online UserGuidecurrent:default= http://docs.cadEnhance.comEntry
CE_VERSION_INFO_URLLink to the ReadMe File for Tool Version changescurrent:default= http://www.cadenhance.com/ce_tool_downloads/ce_win_readme.htmlEntry
HELP_INDEX_URLThis is a pointer to the index.html for the help information available for NetBomcurrent:default= www.cadenhance.com/Documentation/NetBom/index.htmlEntry
LIC_EXP_N_WEEKS_EARLYTest Variable which enables us to reject the license earlycurrent:default= ''Entry
NEW_TOOL_DOWNLOAD_URLThis is where I check for new tool releases current:default= http://www.cadenhance.com/ce_tool_downloads/index.htmlEntry
Back to Top
GENERAL Configuration Settings Back to Top
Configuration SettingDescriptionValue
Current
Default
Type
CE_LIC_FILELocation of LICENSE FILE
The system defaults to the setting of the CE_LIC_FILE Enviornment variable, but that can be overridden with this entry
current:D:/cadEnhance/license/license.dat
default:''
CHOOSE_FILE
CE_WORK_DIRThis is the default location where part folders will be createdcurrent:default= C:/cadEnhance/workdirEntry
LIC_WARNING_WEEKSA warning will popup if the license is due to expire within this number of weekscurrent:default= 4Entry
OUTPUT_FILE_DIRThis is the directory that NetBom will use when it creates output files
current:default= cadEnhance/NetBomEntry
SHOW_DEBUGdetermines whether DEBUG information is shown/hidden in Progress windowcurrent:default= ''CHECK_BUTTON
SHOW_STATdetermines whether normal STATUS information is shown/hidden in Progress windowcurrent:default= 1CHECK_BUTTON
SHOW_WARNdetermines whether WARNINGS are shown/hidden in Progress windowcurrent:default= 1CHECK_BUTTON
TEXT_EDITORText Editor for editing filescurrent:default= ''CHOOSE_FILE
Back to Top
NETLIST_BOM_DIFF Configuration Settings Back to Top
Configuration SettingDescriptionValue
Current
Default
Type
IGNORE_NET_PROP_DIFFSProperty names listed in this comma separated list
will be ignored when properties for the same NET_NAME in the 2 netLists are compared

The following properties are never compared so they should not need to be added
NET_NAME NET_CONNS NET_ID_FROM_PINS NET_ID_XCHECKED NL_INDEX NODE_LIST
HIER_NET_NAME LOGICAL_PATH C_SIGNAL

The user can look at the net_prop difference report and add any properties to this list
that they do not want to include in the comparison

current:default= ''Entry
IGNORE_NODE_PROP_DIFFSProperty names listed in this comma separated list
will be ignored when properties for the same net node (refDes.Pin) in the 2 netLists are compared

The following properties are never compared so they should not need to be added

The user can look at the node_prop difference report and add any properties to this list
that they do not want to include in the comparison

current:default= ''Entry
KEY_PROP_LISTThe BOM_DIFF engine will compare these properties for each refdes in the 2 bom revisions and report if they are different... it is a comma seperated list like: JEDEC_TYPE,VALUE,TYPEcurrent:default= JEDEC_TYPE, VALUE, TYPEEntry
MAX_TABLE_COL_WIDTHIf the data in a column in one of the report table exceeds this length, the code will add a line break for that columncurrent:default= 48Entry
NETLIST1NETLIST1 use for diffing and converting netlists. You choose the pstxnet.dat file and netBom will find the matching pstxprt.datcurrent:D:/Allegro/design/CE_SCHEMATICS/16_6/FOX/200-000307-FOX_SGDD/REV-01X/017_REV_1/worklib/top/packaged/pstxnet.dat
default:''
CHOOSE_FILE
NETLIST2NETLIST2 for diffing BOMs and NETLISTS. You choose the pstxnet.dat file and NetBom will find the matching pstxprt.datcurrent:D:/Allegro/design/CE_SCHEMATICS/16_6/FOX/200-000307-FOX_SGDD/REV-00X/007_REV_1/worklib/top/packaged/pstxnet.dat
default:''
CHOOSE_FILE
OUTPUT_BOM_DIFF_FILEDifference Report for the BOMs (from the pstxprt files), will be automatically named when you run the diff operationcurrent:cadEnhance/NetBom/bom1_diff_bom2.txt
default:''
CHOOSE_FILE
OUTPUT_NET_DIFF_FILEDifference Report for the NETLISTs (from the pstxnet files), will be automatically named when you run the diff operationcurrent:cadEnhance/NetBom/net1_diff_net2.txt
default:''
CHOOSE_FILE
SINGLE_NODE_NET_FILTERSThis Comma Separated List is used to validate SINGLE NODE NETS.
If a NET_NAME contains any of these matches, and it only contains a single node,
it will be counted as filtered, but not included in the SINGLE_NODE_NET report table
current:default= NC_, _NC, NC, ^$UNEntry
DNI_TRUE_VALSThis is a list of the values that make the DO_NOT_INSTALL_PROP true (comma seperated vals like:TRUE,1,YES)current:default= TRUE, 1, YESEntry
DO_NOT_INSTALL_PROPThis is a comma seperated list of properties that will be used to determine if a part is not included in a BOM
Could look like BOM_IGNORE,DNI.
Any part with this Property found True will not be included in the BOM (unlike the BOM_NO_POP_PROP)
current:default= BOM_IGNOREEntry
NO_STRIP_PATHDont strip off the leading directory path for selected filescurrent:default= 1CHECK_BUTTON
REFDES_RENAME_RULESComma Separated List of Was:Is rules to change reference designators in an existing netlist.
This can be used when the user knows they are changing many refdes in the new NetList and they don't want them to show up in the difference reports
Example:
_57$:_S5_S7,_46$:_S4_S6,_02$:_S0_S2,_13$:_S1_S3
this will replace any location ending in
_57 with _S5_S7,
_46 with S4_S6,
_02 with S2_S2,
_13 with S1_S3,

current:default= ''Entry
BOM_NO_POP_PROPThis Setting is used to pick a list of properties that excludes a reference designators from installation, but keeps the part in the BOM for purchasing
When the BOM is generated by the netlist convert routine, any parts with this property found to be true will be printed on a separate row.
current:default= DNIEntry
BOM_NO_PROP_TRUE_VALSThis Setting is used to pick a property and value that excludes reference designators from installation, but keeps the part in the BOM for purchasing
When the BOM is generated by the netlist convert routine, any parts with this property enabled will be printed on a separate row.
current:default= TRUE, YES, 1Entry
Back to Top
NETLIST_CONVERT Configuration Settings Back to Top
Configuration SettingDescriptionValue
Current
Default
Type
DNI_TRUE_VALSThis is a list of the values that make the DO_NOT_INSTALL_PROP true (comma seperated vals like:TRUE,1,YES)current:default= TRUE, 1, YESEntry
DO_NOT_INSTALL_PROPThis is a comma seperated list of properties that will be used to determine if a part is not included in a BOM
Could look like BOM_IGNORE,DNI.
Any part with this Property found True will not be included in the BOM (unlike the BOM_NO_POP_PROP)
current:default= BOM_IGNOREEntry
NO_STRIP_PATHDont strip off the leading directory path for selected filescurrent:default= 1CHECK_BUTTON
REFDES_RENAME_RULESComma Separated List of Was:Is rules to change reference designators in an existing netlist.
This can be used when the user knows they are changing many refdes in the new NetList and they don't want them to show up in the difference reports
Example:
_57$:_S5_S7,_46$:_S4_S6,_02$:_S0_S2,_13$:_S1_S3
this will replace any location ending in
_57 with _S5_S7,
_46 with S4_S6,
_02 with S2_S2,
_13 with S1_S3,

current:default= ''Entry
ADD_PIN_NAME_IN_RINFIf enabled, adds an extra debug level to RINF, showing the PIN_NAME next to the pin numbercurrent:default= 1CHECK_BUTTON
BOM_HEADER_PROPERTIESThis Setting controls what Properties are included in the output BOM from the netlist convert operation
It is entered as a comma separated list, and the order of the Properties will be the order of the columns in the BOM
The user can add any property that is defined for a part
current:default= PART_NUMBER, QTY, REF_DES, DESCRIPTIONEntry
NL_ITEM_CELLS_PER_ROWthis is the number of cells that will be placed in a row for the output csv netlists/partlistscurrent:default= 25Entry
RINF_PRINT_COMPONENTSChooses whether to include Component information to the Converted RINF Netlistcurrent:default= 1CHECK_BUTTON
RINF_PRINT_NETSChooses whether to include Net information to the Converted RINF Netlistcurrent:default= 1CHECK_BUTTON
RINF_PRINT_NET_PROPSdetermines whether Net Properties will be printed in RINF netlistcurrent:default= ''CHECK_BUTTON
RINF_PRINT_PIN_PROPSdetermines whether Pin Properties will be printed in RINF netlistcurrent:default= ''CHECK_BUTTON
BOM_NO_POP_PROPThis Setting is used to pick a list of properties that excludes a reference designators from installation, but keeps the part in the BOM for purchasing
When the BOM is generated by the netlist convert routine, any parts with this property found to be true will be printed on a separate row.
current:default= DNIEntry
BOM_NO_PROP_TRUE_VALSThis Setting is used to pick a property and value that excludes reference designators from installation, but keeps the part in the BOM for purchasing
When the BOM is generated by the netlist convert routine, any parts with this property enabled will be printed on a separate row.
current:default= TRUE, YES, 1Entry
Back to Top